August 2018 Issue Vol.8 No.8
ANALYSIS of MULTI-STOREY BUILDING (G+7) due to SIESMIC LOADING USING ETABS
https://ia601509.us.archive.org/13/items/vol8no0801/vol8no0801.pdfMohd. Zain
Assistant Professor, Department of Civil Engineering,Shri Ramswaroop Memorial University, India
Shubham Srivastava
Assistant Professor, Department of Civil Engineering,Shri Ramswaroop Memorial University, India
Vineet Pathak
Post Graduate, Department of Civil Engineering,Shri Ramswaroop Memorial University, India
Abstract: E-Tabs is the present day leading design software in the market. Many design companies use this software for their project design purposes. So, this project mainly deals with the comparative analysis of the results obtained from the design of a regular and a plan irregular (as per IS 1893) multi storey building structure when designed using E-Tabs software. The principle objective of this project is the comparative study on design and analysis of multi-storeyed building (G+7) by E-Tabs software. E-Tabs is one of the leading software for the design of structures. E-tabs are mostly used to analyze concrete& steel structure, low& high rise buildings, skyscrapers& portal frames structure. In this project we had studied structural behavior of multi-story building (G+7) on E-tabs.
Keywords:Regular, Irregular, Multi-story Building, Steel structure and E-Tabs.
Performance on Domestic Refrigerator by Using Eco-Friendly Refrigerent- A Review
https://ia601506.us.archive.org/22/items/vol8no0802/vol8no0802.pdfPrakash Chaturvedi
M.E. scholar, Mechanical Engineering Department,Radharaman Institute of Technology and Science, Bhopal, Madhya Pradesh, India
Dr. Ajay Singh
Professor and Head, of Mechanical Engineering Department,Radharaman Institute of Technology and Science, Bhopal, Madhya Pradesh, India
Dr. Parag Mishra
Associate Professor, of Mechanical Engineering Department,Radharaman Institute of Technology and Science, Bhopal, Madhya Pradesh, India
Abstract: The depletion of ozone layer and green house effects are worldwide problem. Refrigerants also part of these as it is source of depletion of ozone layer. For this we are going to use eco-friendly refrigerant in place of conventional CFC(chloroflorocarbon) eco-friendly refrigerant are less harmful for environment. Purpose of this experiment is to find the effect produce by different refrigerant in the domestic refrigerator system. This study deals with domestic refrigerator designed to work with three different refrigerant R-410, R-134A, R-404A along with desert cooler .here, comparative analysis is going to be done by using above three refrigerant. In this we are going to use hot water from overhead tank and this hot water is cooled in desert cooler then this water is circulated in water jacket used to subcool the refrigerant. As we know COP of domestic refrigerator in winter is higher than summer so we will use high temperature summer water and try to improve COP and reduction in power consumption.
Keywords:COP,R-134A,R-410,R-404A,coolingjacket, refrigerator, desert cooler.